Since we're now clamping at 100% and rounding, mark as full at that
point. Some batteries will stay in charging state for a long time while
stuck at the same charge level. Just mark them as full to not be
confusing.
The energy values are all that's needed to calculate the battery state.
Using other values for the total capacity results in broken results in
some cases. This matches the output of TLP and i3status, while also
being more straightforward.
../src/modules/network.cpp:22:6: error: ‘optional’ in namespace ‘std’ does not name a template type
22 | std::optional<unsigned long long> read_netstat(std::string_view category, std::string_view key) {
| ^~~~~~~~
../src/modules/network.cpp:7:1: note: ‘std::optional’ is defined in header ‘<optional>’; did you forget to ‘#include <optional>’?
6 | #include "util/format.hpp"
+++ |+#include <optional>
7 | #ifdef WANT_RFKILL
Invisible bar on a `top` layer would still intercept pointer events and
stop them from reaching windows below. Always changing the layer to
to `bottom` along with making bar invisible would prevent that.
Extract two surface implementations from the bar class: GLSSurfaceImpl
and RawSurfaceImpl. This change allowed to remove _all_ surface type
conditionals and significantly simplify the Bar code.
The change also applies PImpl pattern to the Bar, allowing to remove
some headers and fields from `bar.hpp`.
Previous attempts to use auto exclusive zone from gtk-layer-shell failed
because gls was expecting real booleans (`TRUE`/`FALSE`) as set_anchor
arguments. With that being fixed, gtk_layer_auto_exclusive_zone_enable
makes gls handle everything related to the bar resizing.
The only remaining purpose of onConfigureGLS is to log warnings and bar
size changes; gtk-layer-shell code path no longer needs saved width_ or
height_ values.
Other units are all uppercased, so using an uppercased "K" makes it look more consistent (especially when {bandwidthUpBits} or something like that is used).
It's not allowed to bind to a higher version of a wayland protocol than
supported by the client. Binding wlr-foreign-toplevel-manager-v1 v3 to
a generated code for v2 causes errors in libwayland due to a missing
handler for `zwlr_foreign_toplevel_handle_v1.parent` event.
- Add elapsedTime and totalTime to tooltip format arguments
- Catch format exceptions and print error
- Copy mpd connection error message before it gets freed
- Update display after connection to mpd was lost
- Add MPD module option `password`, and document it.
- Add logic to send the password, directly after connecting to
MPD.
Fixes: #576
Signed-off-by: Joseph Benden <joe@benden.us>
Fix MPD connection issues by converting/rewriting module into a
state-machine driven system. It is fully single-threaded and uses
events for transitioning between states. It supports all features
and functionality of the previous MPD module.
Signed-off-by: Joseph Benden <joe@benden.us>